N2 generator can not be started? Check these
The nitrogen generator CANNOT be started? 90% of them are due to these three reasons! ** Is the nitrogen generator unable to start? By following these three steps to troubleshoot, 90% of problems can be quickly resolved! Firstly, check the power supply situation and use a multimeter to measure whether the three-phase voltage is normal (380V ± 10%). Pay special attention to whether there is a phase loss problem. If any abnormal voltage is found, immediately contact an electrician to repair the circuit. Next, check the status of the overload protector. If a trip is found, try resetting it first. However, if frequent trips occur, it may be due to problems with the motor winding or bearings, and further inspection is needed. Finally, try restarting the PLC control system by holding down the power button for at least 5 seconds for a hard restart. If the control panel still does not respond, it may be due to a motherboard or program malfunction. It is recommended to gradually troubleshoot in the order of "power supply protector PLC", as most startup issues can be resolved on their own. If the above methods are ineffective, please contact our 24-hour service hotline in a timely manner. Professional engineers will provide remote guidance or on-site service for you. Remember: Regular maintenance of the electrical system can effectively prevent startup failures!
2025 05/12
-
There is an abnormal display on the control panel of the nitrogen generator? Three step quick investigation!
Is there an abnormal display on the control panel of the nitrogen generator? The three-step quick troubleshooting method helps you easily solve it! Firstly, use a multimeter to measure the 24V control power supply. If the voltage fluctuation exceeds ± 10%, a voltage regulator should be installed, and special attention should be paid to whether the circuit joints are oxidized. Next, perform a hard restart of the PLC system: first turn off the main power, wait for 30 seconds, and then turn it back on. At the same time, press and hold the reset button for more than 5 seconds. Finally, check all signal line connections, with a focus on checking if the display screen cable is loose, and use electronic cleaner to address the oxidation issue at the contact points. If it still cannot be resolved, it may be a motherboard malfunction. It is recommended to contact a professional for repair. Daily suggestion: Clean the control panel with a dry cloth every month to avoid dust accumulation and poor contact. We provide original control component replacement services to ensure the stable operation of your equipment!
2025 05/12
-
Nitrogen generator -help solve the problem existed in laser cutting application
At present, high-power fiber laser equipment on the market has the following common pain points in different cutting and processing scenarios of sheet metal: ① The use of oxygen cutting for thin carbon steel has low efficiency, and the cutting section is prone to hanging soft slag, which can easily cause detachment during subsequent spraying/electroplating; ② The use of oxygen cutting for carbon steel requires high quality of the plate, and factors such as oxidation layer, severe corrosion, and material can seriously affect the stability of cutting quality; ③ Using liquid nitrogen to cut carbon steel has high operating costs and rough cutting surfaces; Severe slag accumulation during liquid nitrogen cutting of medium thick carbon steel, making it impossible to cut thick carbon steel; ④ The use of air cutting for medium thick carbon steel results in severe slag accumulation, which increases the cost of manual polishing, deburring machines, polishing consumables/electricity, and makes the workpiece surface prone to scratches; ⑤ The use of liquid nitrogen for cutting aluminum plates results in severe slag accumulation and poor cross-sectional quality; Air cutting aluminum plates can easily cause overburning and pulverization of the cross-section
2024 08/27
-
Laser cutting nitrogen generator sent to user site in Northeast China
On April 26, 2024, the laser specific nitrogen production system ordered by a customer in Heilongjiang rushed to the customer's site. After the cooperation of our technical department, procurement department, production department, logistics management and other departments, the 150 square meter laser cutting dedicated nitrogen generator ordered by the customer is ready to go and will soon rush to the user's site to meet their production gas needs.
2024 04/26